Abstract Mass loss tests were performed for carbon steel corrosion induced by alternating current,as well as the measurement of polarization curves under AC interference. The results show that the AC corrosion rate of carbon steel follows a power function with the AC interference intensity within AC current density 0~250 A/m2, which concerned in this paper. The effect of AC interference on the polarization curves (1) decreasing the surface reaction resistance, and (2) decreasing both of the anodic and cathodic Tafel slopes. Thereby, the AC corrosion characteristics and rules were well explained and the AC corrosion mechanism was also discussed.
|
Received: 28 May 2010
|
|
Corresponding Authors:
WENG Yongji
E-mail: weng_yj@139.com
|
[1] Williams J F. Corrosion of metals under the influence of alternating current [J].Mater. Prot., 1966, 5(2): 52-53[2] Hanson H R, Smart J. AC Corrosion on a Pipeline Located in an HVAC Utility Corridor [A].Corrosion/2004 [C]. New Orleans, 2004: 04209[3] DD CEN/15280: 2006, Evaluation of a.c.corrosion likehood of buried pipelines -- Application to cathodically protected pipelines [S]. British Standard (BSI), 2006[4] Yunovich M, Thompson N G. AC Corrosion: Corrosion Rate and Mitigation Requirements [A]. Corrosion/2004 [C].New Orleans, 2004: 04206[5] Bertocci U. AC induced corrosion:The effect of an alternating voltage on electrodes under charge-transfer control [J]. Corrosion,1979, 35(5): 211-215[6] Chin D T, Fu T W. Corrosion by alternating current: a study of the anodic polarization of mild steel in Na2SO4 solution [J].Corrosion, 1979, 35(11): 514-523[7] Bolzoni F, Goidanich S, Lazzari L, et al. Laboratory Test Results of AC Interference on Polarized Steel, [A], Corrosion/2003 [C]. San Diego, 2003: 03704[8] Chen J L, Weng Y J, Li Y Y. Measurement of couple current between buried pipeline and coupons [J]. Pipeline Tech. Equip., 2009(5): 19-22 (陈敬龙, 翁永基, 李英义. 检查片与埋地管道间电偶电流的测量 [J]. 管道技术与设备, 2009(5): 19-22)[9] Bolzoni F, Goidanich S, Lazzari L, et al. Laboratory Testing on the Influence of Alternated Current on Steel Corrosion [A], Corrosion/2004 [C]. New Orleans, 2004: 04208[10] Nielsen L V, Nielsen K V, Baumgarten B, et al. AC induced corrosion in pipelines: Detection, characterization and mitigation [A], Corrosion/2004 [C].New Orleans, 2004: 04211 |
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|