|
|
纯Cu和铜包钢在大港土壤环境中的腐蚀行为研究 |
朱 敏 杜翠薇 李晓刚 刘智勇 王胜荣 李建宽 贾静焕 |
北京科技大学材料科学与工程学院 北京 100083 |
|
Corrosion Behavior of Pure Copper and Copper-clad Steels in Soil at Dagang District |
ZHU Min, DU Cuiwei, LI Xiaogang, LIU Zhiyong, WANG Shengrong, LI Jiankuan, JIA Jinghuan |
School of Materials Science and Engineering, University of Science and Technology Beijing,Beijing 100083, China |
引用本文:
朱敏, 杜翠薇, 李晓刚, 刘智勇, 王胜荣, 李建宽, 贾静焕. 纯Cu和铜包钢在大港土壤环境中的腐蚀行为研究[J]. 中国腐蚀与防护学报, 2013, 33(6): 496-500.
ZHU Min,
DU Cuiwei,
LI Xiaogang,
LIU Zhiyong,
WANG Shengrong,
LI Jiankuan,
JIA Jinghuan.
Corrosion Behavior of Pure Copper and Copper-clad Steels in Soil at Dagang District. Journal of Chinese Society for Corrosion and protection, 2013, 33(6): 496-500.
链接本文:
https://www.jcscp.org/CN/
或
https://www.jcscp.org/CN/Y2013/V33/I6/496
|
[1] Zhou P P, Wang S, Li Z Z, et al. Review of corrosion resistant metals for grounding [J]. Elec. Power Constr., 2010, 31(8): 51-54 (周佩朋, 王森, 李志忠等. 耐蚀性金属接地材料研究综述 [J]. 电力建设, 2010, 31(8): 51-54) [2] Li J L. Utility Electrical Grounding Technology [M]. Beijing: China Electric Power Press, 2002 (李景禄. 实用电力接地技术 [M]. 北京: 中国电力出版社, 2002) [3] Yang D W, Li J L. Analysis on corrosion and anti-corrosion measure of substation grounding device [J]. Insul. Surg. Arresters, 2004, (2): 43-46 (杨道武, 李景禄. 发电厂变电所接地装置的腐蚀及防腐蚀措施 [J]. 电瓷避雷器, 2004, (2): 43-46) [4] Weng Y F. Analysis of grounding connection cauterization and the suggestions for material selection [J]. Zhejiang Elec. Power, 2003, (4): 54-56 (翁羽丰. 接地装置腐蚀分析及材料选用建议 [J]. 浙江电力, 2003, (4): 54-56) [5] Li Y Q. Analysis of corrosion behavior of common grounding electrode materials [D]. Beijing: University of Science and Technology Beijing, 2010 (李月强. 常用接地电极材料的腐蚀行为研究 [D]. 北京: 北京科技大学, 2010) [6] Fourez M, Cheno F. The application of Zinc aluminium flake non-electrolytic surface coating [J]. Trans. Inst. Met. Finish., 1993, 71(1): 21-25 [7] Lindsey T. National electrical grounding research project technical report [R]. Massachusetts: The Fire Protection Research Foundation, 2007 [8] Loboda M, Marciniak R. Field corrosion tests in Poland of copper coated steel earthing rods for LPS [A]. 29th International Conference On Lightning Protection [C]. Uppsala, 2008 [9] BS 7430: 1998, Code of practice for earthing [S] [10] UL467, Standard for grounding and bonding equipment [S] [11] Wang Q J, Du Z Z, Wang H B. Characteristics and technical status-quo of the manufacturing process for copper-clad steel wire [J]. Elec. Wire Cable, 2002, (4): 15-27 (王庆娟, 杜忠泽, 王海波. 铜包钢线生产工艺的特点及现状 [J].电线电缆, 2002, (4): 15-27) [12] GB/T 16545-1996, Removal of corrosion products from corrosion test specimens of metals and alloys [S]. Beijing: National Quality Supervision, 1996 (GB/T 16545-1996, 金属和合金的腐蚀试样上腐蚀产物的清除 [S]. 北京: 国家技术监督局, 1996) [13] Li X G, Du C W, Dong C F, et al. Corrosion Behavior and Test of X70 Pipeline Steel [M]. Beijing: Science Press, 2006 (李晓刚, 杜翠薇, 董超芳等. X70钢的腐蚀行为与试验研究 [M]. 北京: 科学出版社, 2006) [14] Fitzgerald K P, Nairn J, Skennerton G, et al. Atmospheric corrosion of copper and the colour, structure and composition of natural patinas on copper [J]. Corros. Sci., 2006, 48(9): 2480-2509 [15] Mayer S T, Muller R. An in situ Raman spectroscopy study of the anodic oxidation of copper in alkaline media [J]. J. Electrochem. Soc., 1992, 139: 426-434 [16] Yu B, Woo P, Erb U. Corrosion behaviour of nanocrystalline copper foil in sodium hydroxide solution [J]. Scr. Mater., 2007, 56: 353-356 [17] Kunze J, Maurice V, Klein L H, et al. In situ STM study of the duplex passive films formed on Cu(111) and Cu(001) in 0.1 M NaOH[J]. Corros. Sci., 2004, 46: 245-264 [18] Rosalbino F, Carlini R, Soggia F, et al. In?uence of rare earth metals addition on the corrosion behaviour of copper in alkaline environment [J]. Corros. Sci., 2012, 58: 139-144
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|