Please wait a minute...
中国腐蚀与防护学报  2026, Vol. 46 Issue (5): 1605-1612     CSTR: 32134.14.1005.4537.2025.354      DOI: 10.11902/1005.4537.2025.354
  研究报告 本期目录 | 过刊浏览 |
Cl- 对Cu在库尔勒土壤模拟液中腐蚀行为的影响
卢壹梁1, 张强1(), 金焱2, 陈云1, 杨丙坤1, 王晓芳1, 韩钰1
1.中国电力科学研究院有限公司 先进输电技术全国重点实验室 北京 100192
2.国家电网有限公司 北京 100031
Effect of Cl--amount on Corrosion Behavior of Cu in Simulated Leaching Solutions of Soil at Korla District of Xinjiang
LU Yiliang1, ZHANG Qiang1(), JIN Yan2, CHEN Yun1, YANG Bingkun1, WANG Xiaofang1, HAN Yu1
1.State Key Laboratory of Advanced Power Transmission Technology, China Electric Power Research Institute, Beijing 100192, China
2.State Grid Corporation China, Beijing 100031, China
引用本文:

卢壹梁, 张强, 金焱, 陈云, 杨丙坤, 王晓芳, 韩钰. Cl- 对Cu在库尔勒土壤模拟液中腐蚀行为的影响[J]. 中国腐蚀与防护学报, 2026, 46(5): 1605-1612.
Yiliang LU, Qiang ZHANG, Yan JIN, Yun CHEN, Bingkun YANG, Xiaofang WANG, Yu HAN. Effect of Cl--amount on Corrosion Behavior of Cu in Simulated Leaching Solutions of Soil at Korla District of Xinjiang[J]. Journal of Chinese Society for Corrosion and protection, 2026, 46(5): 1605-1612.

全文: PDF(10191 KB)   HTML
摘要: 

采用浸泡实验、质量变化和电化学测量等方法,研究了在不同Cl-含量的库尔勒土壤模拟液中Cu的腐蚀行为,溶液的Cl-含量(质量分数)分别为0.05%、0.5%、1.0%和2.0%。经浸泡28 d后,测定了Cu的腐蚀速率、观其表面形貌、并表征腐蚀产物等。结果表明,在低Cl-含量(≤ 0.5%)的条件下,Cu的表面腐蚀程度较轻、腐蚀产物和点蚀坑数量较少;在高含量的Cl- (≥ 1.0%)溶液中,Cu表面腐蚀相对严重、腐蚀产物和点蚀坑数量较多;依Cu的腐蚀速率大小,几种溶液的腐蚀性排序为:2.0% > 1.0% > 0.5% > 0.05%。腐蚀产物由低Cl-浓度下的Cu2O、CuO转变为Cu2O、CuO和Cu2(OH)2CO3,当Cl-含量达到2.0%时,Cu长期浸泡在强腐蚀性的环境中,与溶液中的CO2进一步反应,逐渐生成保护性差的绿色Cu2(OH)2CO3,加剧了腐蚀。电化学分析结果也表明,随着Cl-含量增加至2%,容抗弧半径以及电荷转移电阻减小,腐蚀电流密度增大,Cu腐蚀逐渐严重。

关键词 : Cu,  Cl-,  土壤腐蚀,  腐蚀行为    
Abstract:

Cu has excellent electrical conductivity and corrosion resistance and is one of the ideal materials for grounding electrodes. Herein, the corrosion behavior of Cu was assessed in artificial solutions, simulating the leaching solution of the soil at Korla district of Xinjiang with different Cl- content namely 0.05%, 0.5%, 1.0%, and 2.0% in mass fraction, was studied via immersion test for 28 d and electrochemical measurement etc. The surface morphology, corrosion products, and corrosion rate of Cu were then characterized after the immersion test. The results show that in solutions with low chloride-content (≤ 0.5%), the Cu surface exhibits relatively mild corrosion degree with slight corrosion products and relatively small amount of corrosion pits, which corresponds to better corrosion resistance. Contrast, in solutions with high Cl--content (≥ 1.0%), the surface corrosion of Cu is relatively severe with significant corrosion products and much more corrosion pits. Taking the corrosion rates of Cu in solutions with different Cl--content, the corrosiveness of solutions may be ranked as the following order: 2.0% > 1.0% > 0.5% > 0.05%. In terms of corrosion products, for the solutions with 0.05%, 0.5% and 1.0%Cl-, the formed corrosion products compose mainly of Cu2O and CuO; While for the solution with 2.0%Cl-, the corrosion products compose mainly of Cu2O, CuO, and Cu2(OH)2CO3. As the Cl--content increases, the corrosion rate rises and more corrosion products form. When the Cl--content reaches 2.0%, the Cu may immerse in a strongly corrosive medium for a long time and react with CO2 in the solution, thus gradually generate a less protective greenish basic copper carbonate on the Cu surface, by which the corrosion may be intensified. Electrochemical analysis also indicates that, as the Cl--content increases, the capacitive arc radius as well as Rct (Charge transfer resistance) decreases, the corrosion current density increases, therewith the Cu corrosion becomes more severe.

Key words: Cu    chloride ions    soil corrosion    corrosion behavior
收稿日期: 2025-11-15      32134.14.1005.4537.2025.354
ZTFLH:  TG147  
基金资助:国家电网有限公司科技项目(5500-202358119A-1-1-ZN)
通讯作者: 张强,E-mail:1360120056@126.com,研究方向为电网腐蚀与防护
Corresponding author: ZHANG Qiang, E-mail: 1360120056@126.com
作者简介: 卢壹梁,男,1996年生,博士生
图1  Cu在不同Cl-含量溶液中除锈前后的宏观形貌图
图2  Cu在不同Cl-含量下除锈后的微观形貌图
图3  Cu在不同Cl-含量下的微观形貌和Raman光谱图
图4  Cu在不同Cl-含量下的点蚀形貌图、点蚀深度统计图和点蚀分布概率统计图
图5  Cu在不同Cl-含量下的腐蚀速率
图6  Cu在不同Cl-含量下的电化学阻抗谱
图7  Cu在不同Cl-含量下的阻抗谱拟合等效电路图
Cl- contentRs / Ω·cm2Qf / mF·cm-2Rf / Ω·cm2Qd / mF·cm-2Rct / Ω·cm2Zw / Ω·cm2
0.05%50.82--1.52 × 10-457607.114 × 10-4
0.5%32.02--1.223 × 10-43837-
1.0%21.99--6.897 × 10-536198.883 × 10-4
2.0%10.145.27 × 10-3328.89.083 × 10-6729.7-
表1  Cu在不同Cl-含量下的EIS拟合结果
图8  Cu在不同Cl-含量下的极化曲线
Cl- contentEcorr vs. SCE / mVIcorr / μA·cm-2
0.05%-1832.81
0.5%-2457.85
1.0%-28614.12
2.0%-29815.28
表2  Cu在不同Cl-含量下的腐蚀电位与腐蚀电流密度
[1] Zhao J, Meng X, Ren X, et al. Review on soil corrosion and protection of grounding grids [J]. Materials, 2024, 17: 507
doi: 10.3390/ma17020507
[2] Seppanen J M, Tammi P O, Haarla L C. Underground ground wires for transmission lines: Electrical behavior and feasibility [J]. IEEE Trans. Power Delivery, 2013, 28: 206
[3] Bian Y F, Tang W M, Zhang J, et al. Soil corrosion characteristics of Q235 steel grounding material used in power grid in Anhui Province [J]. J. Chin. Soc. Corros. Prot., 2024, 44: 130
[3] 卞亚飞, 汤文明, 张 洁 等. 安徽省电网接地材料Q235钢的土壤腐蚀特性及规律性研究 [J]. 中国腐蚀与防护学报, 2024, 44: 130
[4] Gao Y F, Du X G, Wang Q W, et al. Corrosion behavior of copper in a simulated grounding condition in electric power grid [J]. J. Chin. Soc. Corros. Prot., 2023, 43: 435
[4] 高义斌, 杜晓刚, 王启伟 等. 铜在电网接地工况下的腐蚀行为研究 [J]. 中国腐蚀与防护学报, 2023, 43: 435
doi: 10.11902/1005.4537.2022.098
[5] Zhang F, Ma S X, Fang H F, et al. Review of evaluation methods of soil corrosivity of grounding grid [J]. Total Corros. Control, 2022, 36(7): 23
[5] 张 锋, 马思想, 房海峰 等. 接地网土壤腐蚀性评价方法综述 [J]. 全面腐蚀控制, 2022, 36(7): 23
[6] Ding L, Poursaee A. The impact of temperature, chlorides and sulfate-reducing bacteria on the corrosion of steel in soil [J]. Environ. Geotech., 2024, 11: 471
[7] Wu X D. Corrosion analysis and countermeasures for grounding net of 500 kV transmission lines [J]. Corros. Prot., 2002, (12): 545
[7] 吴向东. 500 kV输电线路接地网腐蚀分析及防护措施 [J]. 腐蚀与防护, 2002, (12): 545
[8] Zhou P P, Wang S, Li Z Z, et al. Review of corrosion resistant metals for grounding [J]. Electr. Power Constr., 2010, 31(8): 50
[8] 周佩朋, 王 森, 李志忠 等. 耐蚀性金属接地材料研究综述 [J]. 电力建设, 2010, 31(8): 50
[9] Huang T, Shen W T, Xie H P, et al. The effect of power grounding grid material on corrosion characteristics of tower down-lead line [J]. Insul. Surge Arresters, 2024, (1): 93
[9] 黄 涛, 沈文韬, 谢洪平 等. 电力接地网材质对引下线腐蚀特性的影响研究 [J]. 电瓷避雷器, 2024, (1): 93
[10] Yang C Y, Wei G H, Wei T B. Application of copper-clad steel materials in lightning protection and grounding projects in power plants [J]. Shandong Ind. Technol., 2019, (3): 201
[10] 杨成余, 魏广鸿, 魏唐斌. 铜覆钢材料在电厂防雷接地工程中的应用 [J]. 山东工业技术, 2019, (3): 201
[11] Liu L, Li J J, Peng M X, et al. Macro-galvanic corrosion of tower grounding device consisting of graphite and Zn-coated steel in a simulated soil environment [J]. Eng. Fail. Anal., 2022; 135: 106136
doi: 10.1016/j.engfailanal.2022.106136
[12] Wang S, Hu Y B, Li Z Z, et al. Corrosion behavior of three kinds of grounded materials in simulated Shanbei soil solution [J]. Corros. Prot., 2013, 34: 485
[12] 王 森, 胡亚博, 李志忠 等. 三种典型接地极材料在陕北土壤模拟溶液中的腐蚀行为 [J]. 腐蚀与防护, 2013, 34: 485
[13] Chen S F, Tao X L, Zhu Y B, et al. Study on the grounding material and soil contact resistance determination [J]. Electr. Eng., 2023, 24(3): 31
[13] 陈四甫, 陶晓莉, 朱渊博 等. 接地材料与土壤接触电阻测定方法研究 [J]. 电气技术, 2023, 24(3): 31
[14] Chen J, Qin Z, Shoesmith D W. Long-term corrosion of copper in a dilute anaerobic sulfide solution [J]. Electrochim. Acta, 2011, 56: 7854
doi: 10.1016/j.electacta.2011.04.086
[15] Ramamurthy S, Chen J, Zagidulin D, et al. The influences of traces of oxygen and sulfide on the corrosion of copper in concentrated chloride solutions [J]. Corros. Sci., 2024; 233: 112047
doi: 10.1016/j.corsci.2024.112047
[16] Rosborg B, Kosec T, Kranjc A, et al. Electrochemical impedance spectroscopy of pure copper exposed in bentonite under oxic conditions [J]. Electrochim. Acta, 2011, 56: 7862
doi: 10.1016/j.electacta.2011.03.111
[17] Wang H X, Yang Y, Zhao P Z, et al. Numerical simulation of corrosion characteristics of copper grounding grid materials in extreme weather [J]. Eng. Rep., 2025, 7: e70227
[18] Syafiqah Mohd Azmi N, Mohamed D, Yuhyi Mohd Tadza M. Effects of various relative humidity conditions on copper corrosion behavior in bentonite [J]. Mater. Today Proc., 2022, 48: 801
[19] Shao Y P, Yan A J, Jin Y, et al. Effect of iron-aluminum oxide on corrosion behavior of copper for grounding grids in red soil [J]. Corros. Sci. Prot. Technol., 2015, 27: 463
[19] 邵玉佩, 闫爱军, 金 雨 等. 红壤中铁铝氧化物对铜接地极材料的腐蚀行为 [J]. 腐蚀科学与防护技术, 2015, 27: 463
doi: 10.11903/1002.6495.2014.317
[20] Zhao Y B, Liu X J, Liu N Z, et al. Cu corrosion in supernatant and sedimentation of bentonite slurry containing chloride [J]. Corros. Sci., 2024, 237: 112308
doi: 10.1016/j.corsci.2024.112308
[21] Zhu Y C, Liu G M, Liu X, et al. Corrosion behavior of Q235 steel in three typical soil environments [J]. Mater. Mech. Eng., 2019, 43(10): 15
doi: 10.11973/jxgccl201910004
[21] 朱亦晨, 刘光明, 刘 欣 等. Q235钢在3种典型土壤环境中的腐蚀行为 [J]. 机械工程材料, 2019, 43(10): 15
doi: 10.11973/jxgccl201910004
[22] Li H L, Wan H X, Du C W. Corrosion behavior of galvanized steel in typical soil environments [J]. Corros. Prot., 2018, 39: 387
[22] 李海玲, 万红霞, 杜翠薇. 镀锌钢在多种典型土壤环境中的腐蚀行为 [J]. 腐蚀与防护, 2018, 39: 387
[23] Wu J W, Du C W, Li X G, et al. Indoor study of corrosion behavior of low carbon steels in Ku'erle soil [J] Corros. Sci. Prot. Technol., 2004, 16: 280
[23] 武俊伟, 杜翠薇, 李晓刚 等. 低碳钢在库尔勒土壤中腐蚀行为的室内研究 [J]. 腐蚀科学与防护技术, 2004, 16: 280
[24] Wu J W, Li X G, Du C W, et al. Short-term corrosion behavior of X70 steel in Ku'erle soil [J]. J. Chin. Soc. Corros. Prot., 2005, 25: 15
[24] 武俊伟, 李晓刚, 杜翠薇 等. X70钢在库尔勒土壤中短期腐蚀行为研究 [J]. 中国腐蚀与防护学报, 2005, 25: 15
[25] Li S, Wang J, He H L, et al. Research on corrosion behavior of carbon steel grounding material in oxygenated soil solution [J]. Electr. Eng., 2021, (9): 148
[25] 李 松, 王 荆, 何华林 等. 碳钢接地材料在含氧土壤溶液中的腐蚀行为研究 [J]. 电工技术, 2021, (9): 148
[26] Duan H J. Investigation of several issues in the application of copper-clad steel in grounding networks [J]. China New Telecommun., 2020, 22(3): 88
[26] 段华杰. 铜覆钢在接地网中应用中的若干问题探究 [J]. 中国新通信, 2020, 22(3): 88
[1] 赵先锐, 戴中国, 李战江, 徐育烺, 张会霞, 李旺. 添加Y、Hf对AlCoCrFeNi高熵合金涂层在NaCl溶液中的腐蚀行为的影响[J]. 中国腐蚀与防护学报, 2026, 46(5): 1549-1559.
[2] 叶海锋, 沈书成, 陈江华. 增材制造316L不锈钢在不同温度海水环境中的腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(5): 1569-1578.
[3] 马欢欢, 吕晟东, 钱溢鑫, 林勇, 郝湘平, 张达威, 王鲁宁. 三水醋酸钠相变储热体系中铜换热管的局部腐蚀与寿命预测[J]. 中国腐蚀与防护学报, 2026, 46(4): 1045-1057.
[4] 黄涛, 朱宇, 邓宇, 王岐山, 田一晨, 陈旭. 氢对X65钢及其焊缝力学性能及腐蚀行为影响[J]. 中国腐蚀与防护学报, 2026, 46(4): 1107-1116.
[5] 杨鑫, 车欣, 卢玉章, 黄亚奇, 王栋, 申健. 一种低Re二代单晶高温合金的热腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(4): 1159-1168.
[6] 张晶晶, 张震, 赵占勇, 白培康, 周杰. NaHSO3 添加对445J2铁素体不锈钢在NaCl溶液中腐蚀行为影响研究[J]. 中国腐蚀与防护学报, 2026, 46(4): 1197-1206.
[7] 李自立, 王欣纪, 田春洋, 叶沛聪, 刘海乔, 何成刚, 刘吉华. NaCl溶液温度和含量对热处理后钢轨腐蚀行为的影响[J]. 中国腐蚀与防护学报, 2026, 46(4): 1279-1288.
[8] 李永坤, 周佳顺, 王友彬, 高锋, 王欣鹏, 汤宏群. 腐蚀产物对锌合金镀层切边腐蚀行为的影响[J]. 中国腐蚀与防护学报, 2026, 46(3): 703-716.
[9] 赵密锋, 胡芳婷, 刘艳明, 宋文文, 谢俊峰, 吕祥鸿, 代盼, 胡航波. 含氧注气驱高Ca2+ 浓度工况下C110钢腐蚀产物膜演变及腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(3): 821-832.
[10] 刘晨辉, 刘光明, 朱炎彬, 卢壹梁, 张玲玲, 黄泽邦. 模拟盐碱土渗入地下海水对纯锌腐蚀行为影响的研究[J]. 中国腐蚀与防护学报, 2026, 46(3): 864-874.
[11] 冯晨旭, 崔腾飞, 徐璐, 张昕宇, 崔中雨. A588耐候钢在极寒大气环境下的腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(3): 875-882.
[12] 贺佳, 李欢, 覃世军, 芦伟, 汪卫华, 储德林. 高温流动液态锂铅对氧化物弥散强化钢的长时间腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(3): 911-918.
[13] 陈旭, 杨浩, 田一晨, 张国庆, 宋博, 王岐山, 肖成灿. D36低碳钢在不同模拟海洋环境中初期腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(2): 549-557.
[14] 严建成, 冯向东, 卢得勇, 李进, 孟鹏军, 娄宝辉, 郭健, 李正涛, 朱正旺. 一种Cu-Zn基高熵合金在硬水中的腐蚀行为研究[J]. 中国腐蚀与防护学报, 2026, 46(2): 601-610.
[15] 王乙初, 刘天龙, 张思倩, 赵利, 骆智超, 郑开宏. 含V、W高Mn奥氏体耐热钢在熔融Na2SO4 中的热腐蚀行为[J]. 中国腐蚀与防护学报, 2026, 46(2): 620-628.