| THE EFFECT OF LOCALIZED CORROSION ON FRETTINGATTACK OF 316l STAINLESS STEEL IN 0.9%NaCl SOLUTION |
| Jianzhong Yan;; |
| 北京科技大学腐蚀与防护中心 腐蚀、磨蚀与表面技术开放研究实验室 |
|
Cite this article:
Jianzhong Yan. THE EFFECT OF LOCALIZED CORROSION ON FRETTINGATTACK OF 316l STAINLESS STEEL IN 0.9%NaCl SOLUTION. J Chin Soc Corr Pro, 2000, 20(4): 237-242 .
|
|
|
Abstract The effect of localized corrosion,such as crevice corrosion and potting on fretting attack of solution annealed 316L stainless steel in saline solution, has been studied with ball-plane contacted fretting test system.The results suggested that fretting induced remarkable corrosion,and the combination of fretting and crevice-like cindition made the material suffer severe corrosion damage.The oxidation of the fretting corrosion product resulted in alkaline deposit on the surface outside of the fretted center,which would play an important role in the fretting process.Debris could play some apparent role on the damage when fretting carried on under high anodic polarization condition.The concentration of debris on the edge of fretting area might accelerate the occurrence of pitting ,which made great contribution to the damage and the expansion of fretting scars.
|
|
Received: 16 August 1999
|
|
|
[1] Waterhouse R B. Fretting Corrosion[M]. New York:Pergamon Press, 1972 [2] Waterhouse R B. Fretting Fatigue[M]. London:Appl. Sci. Publ. LTD, 1981 [3]李诗卓,董祥林.材料的冲蚀磨损与激动磨损[M].北京:机械工业出版社,1987 [4]李京紫.激动磨损与防护技术[M].西安:陕西科学技术出版社,1992 [5] Silva R, Barbosa M A, Rondet B, et al. Impedance and photoelectrochemical measurement on passive films formed on metallicbiomaterials[J]. Br. Corros. J., 1990, 25(2): 136 [6] Lewis G, Daigle K. Electrochemical behavior of Ti-6Al-4V alley in static biosimulating solutions[J]. J. of Applied Biomaterials, 1993,4:47 [7] Brown S A. Simpson J P. Biomed J. Crevice and fretting corrosion of stainless-less plate and screws[J]. J. Biomed. Mater. Res., 1981,(15):867 [8] Prabhat Kamar. Anthony J Hick, Asphahani A I, et al. Properties and characteristics of cast, wrought, and powder metallurgy(P/M)processed cobalt-chromium-molybdenum materials[A]. In: Fraker A C, Griffin C D, eds. Corrosion and Degradation of ImplantMaterials, ASTM STP859[C]. Philadelphia. 1985. 30 [9] Brown S A,Meritt K. Fretting Corrosion in saline and serum[J] .J. Biomed.Mater. Res., 1981, (15):479 [10] John P Sheehan,Charles R Morin, Kenneth F. Packer. Study of stress corrosion cracking susceptibility of type 316L stainless steel invitro[A]. In: Fraker A C, Griffin C D, eds. Corrosion and Degradation of Implant materials, ASIM SIP859[C], Philadelphia. 1985. 57 [11] Taira M, Lautenschlager E P. In vitro corrosion fatigue of 316L cold worked stainless steel[J] .J. Biomed. Mater. Res., 1992, (26):1171 [12] Mevellec C, Burleigh T D, Shanbhag A S. Corrsion in modular femoral hip prostheses: A study of 22 retrieved implants[A]. Southern,Biomedical Engineering Conference Proceedings IEEE[C], Piscataway, NJ, USA, 96TH8154, 1996. 3 [13] Musolino M C,Pettit F S,Burleigh TD, et al. Analysis of corrosion in sstainless steel total hip prostheses[A]. Southern BiomedicalEngineering Conference-Proceedings IEEE[C]. Piscataway, NJ, USA 96TH8154. 1996. 5 [14] Brown S A, Simpson J P. Grevice and freetig corrosion of stainless-steel plate and screws[J]. J. Biomed.Mater. Res., 1981, (15):867 [15] Suh, N P.The delamination theory of wear[J] .Wear. 1973, (25): 111 [16] Sproles E S, Gaul D J, Duquette D J., Fundamentals of Tribology[M]. Eds.Suh N P, Sake N, MIT. 1980.585 [17] Stowers I F, Rabinowica, E. Spherical particles formed in the fretting of silver[J] .J.Appl.Phys., 1972, (43):2485 [18] Hurricks P L.The occurrence of spherical particles in fretting wear[J]. Wear, 1974, (27):319 |
| No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
| |
Shared |
|
|
|
|
| |
Discussed |
|
|
|
|