Critical Crack Sizes of CNG Cylinder Steel in H2S Environment |
;;Xiaoping Shan;Bangxian Li |
北京工业大学机电学院 |
|
|
Abstract Three groups of specimens of CNG cylinder steels,4130X and 30CrMo,were tested in dense and moderate H2S solutions.By using modified WOL specimens loaded with bolts,we obtained KISCC in H2S environment,as well as K1C in air.The critical crack sizes of different materials
in H2S environment were thus figured out,and the curves with working pressures and equivalent stress to critical crack size were plotted.The results show thatK1C of those specimens were all in a high level,thus with good fracture toughness in normal nvironment.However,KISCC in H2S environment ranged from 20% to 40% of K1C.For two groups of specimens made of CNG steel 4130X but from different vendors,their KISCC are 30% difference and their critical crack sizes are 80% difference.
|
Received: 08 May 2004
|
|
[1]Fred F Lyle,Jr.Evaluation of the effects of natural gas contaminantson corrosion in compressed natural gas storage systems:section 2[A].U.S.Southwest Research Institute,1989 [2]NACE MRO175-97.Sulfide stress cracking resistant metallic mate-rials for oilfield equipment[S].1997 [3]NACE TM0177-96.Laboratory testing of metals for resistance tospecific forms of environmental cracking in H2S environments[S].1996 [4]EFC Publications No.16.Guidelines on materials requirements forcarbon and low alloy steels for H2S-containing environments in oiland gas production[S].Reprinted with Corrections,1998 [5]GB17820-1999.Natural gas[S].1999(GB17820-1999.天然气[S].1999) [6]GB12445.3-90.Stress corrosion test method of pre-crack wedge-open loading(WOL)specimens of high strength alloy steel[S].1990(GB12445.3-90.高强度合金钢锲型张开加载(WOL)予裂纹试样应力腐蚀实验方法[S].1999) [7]Novak S R,Rolfe S T.Modified WOL specimen forKISCCenviron-mental testing[J].Journal of Materials,JMLSA,1969,4(3):710~720 [8]Assessment of integrity of structures containing defects[S].CEGBReport-R/H/R6-ReV.3,London,1986 [9]ASME.Boiler and pressure vessel code,section XI:rules for inserviceinspection of nuclear power plant components,appendix A,analysisof flaws,2001 [10]Blackburn P R,Rana M D.Acoustic emission testing and structuralevaluation of seamless,steel tubes in compressed gas service[J].J.Pressure Vessel Technology,1986,108(5):234~240 [11]Fan Q S.Stress Analysis and Intension Design of Pressure Vessel[M].Beijing:Atomic Energy Publishing Company,1983,8:19~23(范钦珊.压力容器的应力分析与强度计算[M].北京:原子能出版社,1983,8:19~23) [12]Fred F Lyle,Jr.Evaluation of the effects of natural gas contami-nants on corrosion in compressed natural gas storage systems:sec-tion 4[A].U.S.Southwest Research Institute,1989 |
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|