STUDY ON THE ELECTROCHEMICAL SENSING SYSTEMFOR MONITORING/DETECTING MARINE STEEL CORROSION
Xiaoshan Wan;Bin Tian;Shizhe Song
天津大学材料学院
Download:  PDF(168KB) 
Export:  BibTeX | EndNote (RIS)      
Abstract  An electrochemical sensor constraining the measurin g current through a pinhole for directly monitoring/detecting corrosion of marin e steel construction was designed and made.Props with powerful magnetic magnet a nd a retractable tentacle were employed to fix on the surface of ferromagnetism metal material such as iron and steel and to ensure the electricity contact.The influence of structure parameters on its measurement area were discussed.A set o f instrument fitting field measurement,based on the control of singlechip comp uter was designed and made.The field measurements on bare steel tubular stakes o f No.27 container berth in Tanggu were successfully conducted,and the suitabilit y of the designed system in the circumstance of field corrosion monitoring/detec ting was proved.
Key words:  corrosion monitoring/detecting      electrochemical sensor      measurement system      
Received:  13 October 2000     
ZTFLH:  TG174  
Corresponding Authors:  Xiaoshan Wan   

Cite this article: 

Xiaoshan Wan; Bin Tian; Shizhe Song. STUDY ON THE ELECTROCHEMICAL SENSING SYSTEMFOR MONITORING/DETECTING MARINE STEEL CORROSION. J Chin Soc Corr Pro, 2001, 21(3): 182-187 .

URL: 

https://www.jcscp.org/EN/     OR     https://www.jcscp.org/EN/Y2001/V21/I3/182

[1]YojuImao,KazuoOsato,HirojiNakauchi.Calculationofthepolarizationcurrentdistributionanditseffectonthevaluesofthepolarizationresistanceobtainedinmonitoringofcorrosionbylinearpolarizationmethod[C].BoshokuGijutsu,1986,35(12):689-697
[2]SudohS ,HaruyamaS .Currentprofilebetweenprobeelectrodeandlargescaleburiedinstallationinpolarizationresistancemea surement[J].CorrosionEngineering1990,39(2):55-66
[3]FuekiK ,ShiokawaJ,SuzukiS .ACorrosionmonitoringsensorformarinesteelstructures[A].Int.MeetingonChemicalSensors[C],Fukueka,1983,9:9-12
[4]KazumiMatsuoka,SatoshiIto.Electrochemicaldiagnosticanalysisforcorrosiondeteriorationofsteelstructure[J].Zairyo-to-Kankyo,1992,41(10):698-705
[5]FeliuS ,GonzalezJA ,AndradeC ,FeliuV ,On-sitedeterminationofthepolarizationresistanceinareinforcedconcretebeam[J].Corrosion,1988,44(10):761-765
[6]FeliuS ,GonzalezJA ,EscuderoML ,FeliuSJr.Possibilitiesofthe“guardring”fortheconfinementoftheelectricalsignal.Po larizationMeasurementsofReinforcements[A].Corrosion89[C],April,17-21,1989,paperNo.623
[7]FeliuS ,GonzalezJA ,FeliuSJr,AndradeMC .Confinementoftheelectricalsignalforinsitumeasurementofpolarizationresis tanceinreinforcedconcrete[J].ACIMateralsJournal,1990,87(5):457-460
[1] ZHU Zejie,ZHANG Qinhao,LIU Pan,ZHANG Jianqing,CAO Fahe. Application of Microelectrochemical Sensors in Monitoring of Localized Interface pH[J]. 中国腐蚀与防护学报, 2019, 39(5): 367-374.
[2] Shizhe Song. Corrosion Electrochemical Sensor for Welded Structures in Aquatic Environment[J]. 中国腐蚀与防护学报, 2006, 26(6): 329-331 .
No Suggested Reading articles found!