| COMPARING DIFFERENT CRITERIA OF EPR METHOD TO EVALUATE THE SUSCEPTIBILITY TO INTERGRANULAR CORROSION |
| Zhongping Gao;Fancai Chen;Changjiu Zhao |
| 湖南大学化学化工学院 |
|
Cite this article:
Zhongping Gao; Fancai Chen; Changjiu Zhao. COMPARING DIFFERENT CRITERIA OF EPR METHOD TO EVALUATE THE SUSCEPTIBILITY TO INTERGRANULAR CORROSION. J Chin Soc Corr Pro, 2000, 20(4): 243-247 .
|
|
|
Abstract The susceptibility to intergranular corrosion(IGC)for 1Cr18Ni9Ti stainless steel has been studied by the electrochemical potentiodynamic reactivation(EPR)method and the oxalic acid etch test.Different criteria used in EPR test to evaluate the tendency of IGC have been analyzed in detail.All criteria are well correlated with the degree of sensitization.With increasing sensitization time,the value of criteria increases.Furthermore all criteria can sensitively and quantitatively reflect the diffeerence of material with lower sensitization In all criteria,the current ratio ir/ia and charge ratio Qr/Qa have better repeatability than the reactive current ir or the reactive charge Qr.The criteria of charge (Qr,Qr/Qa)are more sensitive than the criteria of current(ir, ir/ia).
|
|
Received: 21 July 1999
|
|
|
[1] Duffaut F, Pouzet J P, Lacombe P. Potentiostatic study of structural modifications caused in a Ni-Cr-Fe alloy by heat treatment at 650℃[J]. Corrosion Science, 1966, 6(2):83-85 [2] Clarke W L, Carlson P C. Nondestructive measurement of sensitization of stainless steel: relation to high temperature stress corrosionbehavior[J]. 1980, 19(3): 16 - 23 [3] Akashi M. Kawamoto T.The effect of molybdenum addition on SCC susceptibility of stainless steels in oxygenated high temperature water[J]. Corrosion Engineering, 1978, 27(4): 165 - 171 [4]方智,张玉林,吴荫顺,等.电化学动电位再活化法评价308L不锈钢的晶间腐蚀敏感性[J].腐蚀科学与防护技术,1996, 8(2):87-93. [5] Cihal V. Advances in the potentiodynamic reactivation method[J] .Werkstoffe und Korrosion, 1986, 37(11):587 - 591 [6] Scully J R. Kelly R G. An electrochemical test for detecting the intergranular corrosion susceptibility of a duplex stainless steel[J].Corrosion, 1986, 42(9): 537-542 [7] Frangini S. Mignone A. Modified electrochemical potentiokinetic reactivation mothod for detecting sensitization in 12wt% Cr ferriticstainless steels[J]. Corrosion, 1992, 48(9):715 - 726 [8] ASTM Book of Standards[S] .Vol, 10, A262, ASTM, Philadelphia, Pennsylvania, 1981 |
| No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
| |
Shared |
|
|
|
|
| |
Discussed |
|
|
|
|