Please wait a minute...
中国腐蚀与防护学报  1990, Vol. 10 Issue (4): 330-338    
  研究报告 本期目录 | 过刊浏览 |
恒电量法测定电化学腐蚀动力学参数的原理与测量系统
赵常就;陈范才;陈训娥
湖南大学化学化工系;湖南大学化学化工系;湖南大学化学化工系
THE PRINCIPLE OF MEASURING KINETIC PARAMETRS OF ELECTROCHEMICAL CORROSION SYSTEM BY COULOSTATIC PERTURBATION METHOD AND ITS MEASURING SYSTEM
Zhao Changjiu Chen Fancai Chen Xune (Hunan University)
全文: PDF(533 KB)  
摘要: 研究了恒电量腐蚀速率仪,建立了恒电量仪与微计算机联机在线测量系统,可用以评定涂装金属的耐蚀性.使用该测量系统,只需一次微极化即可获得重要参数值-极化阻力 R、界面双层微分电容 Cl溶液电阻 R_S 及涂膜层电阻 R、涂膜层电容 Cl。对于非涂装体系,经两次强极化正可获得塔菲尔常数 b、b,结合 Stern-Geary 方程便可算出腐蚀电流 I。
Abstract:A corrosion rate meter for coulostatic perturbation method has been made and a on-line measuring system combined with microcomputer is set up.It can be used to evaluate the corrosion resistance of coated metals by coulostatic perturbation method. Important parameters such as R_p,R_f,C_u,C_f and R_s can be obtained in experiment with only for once weak polarization.For uncoated metal systems,TAFEL slopes b_a and b_c can be obtained with twice strong polarization,and the corrosion current I_(corr)can be calculated with the aid of STERN-GEARY equation.
收稿日期: 1990-08-25     
基金资助:中科院腐蚀科学开放研究实验室资助项目的部份工作;;机电部基金委资助项目的部份工作

引用本文:

赵常就;陈范才;陈训娥. 恒电量法测定电化学腐蚀动力学参数的原理与测量系统[J]. 中国腐蚀与防护学报, 1990, 10(4): 330-338.
. THE PRINCIPLE OF MEASURING KINETIC PARAMETRS OF ELECTROCHEMICAL CORROSION SYSTEM BY COULOSTATIC PERTURBATION METHOD AND ITS MEASURING SYSTEM. J Chin Soc Corr Pro, 1990, 10(4): 330-338.

链接本文:

https://www.jcscp.org/CN/      或      https://www.jcscp.org/CN/Y1990/V10/I4/330

[1] Delahay,P.,J.Phys.Chem.,66,2204 (1962)
[2] Kanno,K.;Syzuki,M.and Sato,Y.,J.Electrochem.Soc.,125,1389(1978)
[3] Kanno,K.,Syzuki,M.and Sato,Y.,Corros.Sci.,20,1059(1980)
[4] Van Leeuwen,H.P.,Electrochim.Acta,23,207 (1978)
[5] 赵常就、陈范才,腐蚀与防护,No.4,P8(1984)
[6] 赵常就、陈范才,腐蚀与防护,No.2,P31(1985)
[7] 赵常就、陈金年、刘沙,表面技术,No.4,P49(1938)
[8] 赵常就、陈范才、陈训娥,中国腐蚀与防护学报,10(4) ,317(1990)
[9] 曹楚南,腐蚀电化学原理,化学工业出版社,1985,P139 325
[10] 南京大学数学系计算数学专业编,最优化方法,科学出版社,1984年
No related articles found!