Please wait a minute...
J Chin Soc Corr Pro  2007, Vol. 27 Issue (3): 176-180     DOI:
Research Report Current Issue | Archive | Adv Search |
Study on the performance of silver-silver chloride reference probe
;;
海军工程大学
Download:  PDF(272KB) 
Export:  BibTeX | EndNote (RIS)      
Abstract  A silver-silver chloride reference probe has been made by electrolytic method and its structure and ingredient is characterized with EPMA. A series of its performances are studied. The results show that the silver-silver chloride reference probe has good properties such as stability and precision in 3.5%NaCl, the little potential difference between two probes in long term, the response property to temperature and the concentration of Cl-, antipolarization. Thus the probe studied probably can be used as sense organ in the precision instrument of electrochemical measurement.
Key words:  Ag/AgCl      reference probe      electrolytic method      
Received:  15 August 2006     
ZTFLH:  TG174。3  
Service
E-mail this article
Add to citation manager
E-mail Alert
RSS
Articles by authors

Cite this article: 

. Study on the performance of silver-silver chloride reference probe. J Chin Soc Corr Pro, 2007, 27(3): 176-180 .

URL: 

https://www.jcscp.org/EN/     OR     https://www.jcscp.org/EN/Y2007/V27/I3/176

[1]Amaya K,Aoki S.Effective boundary element methods in corrosionanalysis[J].Engineering Analysis with Boundary Elements,2003,27:507-519
[2]Akira T,Toshiki K.Potential distribution measurement in galvaniccorrosion of Zn/Fe couple by means of Kelvin probe[J].Corros.Sci.,2000,42:655-673
[3]Sun M X.Situation and development of technology on cathodic ofprotection of vessel[J].Vessel Technol.,2001,2:44-46(孙明先.舰船阴极保护技术的现状及发展[J].舰船科学技术,2001,2:44-46)
[4]Wang Y H,Zhang T,Wang J.Application of Kelvin probe techniquein the studies of atmospheric corrosion[J].J.Chin.Soc.Corros.Prot.,2004,24(1):59-64(王燕华,张涛,王佳.Kelvin探头参比电极技术在大气腐蚀研究中的应用[J].中国腐蚀与防护学报,2004,24(1):59-64
[5]Tian B,Hu M,Li C F.State of the art and future trends of Ag/AgClreferences for high temperature and high pressure aqueous systems[J].J.Chin.Soc.Corros.Prot.,2003,23(6):371-372(田斌,胡明,李春福.高温高压水溶液用Ag/AgCl参比电极研究现状及发展趋势[J].中国腐蚀与防护学报,2003,23(6):371-372)
[6]Shi X Y,Qiu F R,Zheng W X.Investigation of high stability refer-ence electrode in sea water[J].China Offshore Platform,1999,14(3):13-14(石小燕,邱富荣,郑伟希.海水中高稳定性参比电极的研制[J].中国海洋平台,1999,14(3):13)
[7]Yin Y J,Xi Z K.Concise Tutorial for Physical Chemistry[M].Bei-jing:High Education Press,1997(印永嘉,奚正楷.物理化学简明教程[M].北京:高等教育出版社,1997)
[8]Staff Room for Physical Chemistry of Tianjin University.PhysicalChemistry[M].Beijing:High Education Press,1998(天津大学物理化学教研室编.物理化学[M].北京:高等教育出版,1998)
[9]Miao Y.Research on all solid-state reference electrode used indeep marine[D].Chongqing:Chongqing University,2003(苗燕.深海用全固态参比电极的研究[D].重庆:重庆大学,2003)
[10]Lu X C.The model and countermeasures of shaft-rate electric fieldof a ship[D].Wuhan:Naval University of Engineering,2004(卢新城.舰船轴频电场模型及其消除方法[D].武汉:海军工程大学,2004)
[11]Liu Y H.Technology of Electrochemical Measurement[M].Bei-jing:Beijing Institute of Aeronautics and Astronautics Press,1989(刘永辉.电化学测试技术[M].北京:航空航天学院出版社,1989)
[1] WANG Zechen, LIN Jun, YANG Guoqing, LIANG Shangqing. Effect of Nafion Film on Corrosion Resistance and Electric Field Response of Marine Electric Field Electrode[J]. 中国腐蚀与防护学报, 2019, 39(6): 581-587.
[2] XIN Yonglei,XU Likun,YIN Pengfei,WANG Juntao,LI Xiangbo. Factors Influencing Potential Stability of a Solid
Ag/AgCl Reference Electrode
[J]. 中国腐蚀与防护学报, 2013, 33(3): 231-234.
[3] Bin Tian; Ming Hu; Chunfu Li. STATE OF THE ART AND FUTURE TRENDS OFAg/AgCl REFERENCE ELECTRODES FOR HIGHTEMPERATURE AND HIGH PRESSURE AQUEOUS SYSTEMS[J]. 中国腐蚀与防护学报, 2003, 23(6): 370-374 .
No Suggested Reading articles found!