Please wait a minute...
J Chin Soc Corr Pro  2006, Vol. 26 Issue (6): 329-331     DOI:
Research Report Current Issue | Archive | Adv Search |
Corrosion Electrochemical Sensor for Welded Structures in Aquatic Environment
;Shizhe Song
中国石油天然气管道工程有限公司
Download:  PDF(220KB) 
Export:  BibTeX | EndNote (RIS)      
Abstract  In this paper, an electrochemical sensor to detect corrosion in aquatic environment was designed and set up.But contact and angular contact welding seam corrosio detection sensors were designed respectively. Based on local enclosure theory an enclosed electrolytic cell was built up by contacting the front section of insulated cavity with the surface of the component to be tested. Magnets were employed as contacting fix up on the structre surface. Current enclosing capability of the sensor was erified by the experiments. Employing the sensor developed, measurement were carried out at welding seam and different locations of the base metal on simulating welded specimens in NaCl solution of 3.5%. The results show that Rpof welding seam and base metal exhibit different trends against time, and both EIS spectrums diferentiate with each other evidently. It shows that the corrosion situations at different sections can be well distinguished by the sensor.
Key words:  welded structure      electrochemical sensor      corrosion detection      
Received:  12 July 2005     
ZTFLH:  TG174  

Cite this article: 

Shizhe Song. Corrosion Electrochemical Sensor for Welded Structures in Aquatic Environment. J Chin Soc Corr Pro, 2006, 26(6): 329-331 .

URL: 

https://www.jcscp.org/EN/     OR     https://www.jcscp.org/EN/Y2006/V26/I6/329

[1]Watanabe Takehiko,Ei Kazuo,Nakamura Harumasa.Pitting corro-sion and measuring localized corrosion potential in welds of austeniticstainless steels[J].Yosetsu Gakkai Ronbunshu/Quarterly Journal ofthe Japan Welding Society,1985,3(1):48-54
[2]Zhao H,Gao J,Shi Z M,et al.Analysis of corrosion failure on weldsof water supply pipe[J].Corros.Sci.Prot.Technol.,2004,16(2):105-106(赵晖,高俭,史志明等.自来水管焊缝腐蚀失效分析[J].腐蚀科学与防技术,2004,16(2):105-106)
[3]Wan X S.Study on the electrochemical sensing technique of iron andsteel corrosion monitoring/detecting in marine environment[D].Tianjin:Tianjin University Dissertation,2000(万小山.钢铁材料水环境腐蚀监/检测电化学传感技术研究[D].天津:天津大学学位论文,2000)
[4]Zhang W Y.Fundamental Theory of Welding Metallurgy[M].Bei-jing:Mechanical Industry Press,1991(张文钺.焊接冶金学(基本原理)[M].北京:机械工业出版社,1991)
[1] ZHU Zejie,ZHANG Qinhao,LIU Pan,ZHANG Jianqing,CAO Fahe. Application of Microelectrochemical Sensors in Monitoring of Localized Interface pH[J]. 中国腐蚀与防护学报, 2019, 39(5): 367-374.
[2] ;. Preparation and performance study of light-group sensitive coating with N、O complex[J]. 中国腐蚀与防护学报, 2007, 27(5): 296-302 .
[3] Xiaoshan Wan; Bin Tian; Shizhe Song. STUDY ON THE ELECTROCHEMICAL SENSING SYSTEMFOR MONITORING/DETECTING MARINE STEEL CORROSION[J]. 中国腐蚀与防护学报, 2001, 21(3): 182-187 .
No Suggested Reading articles found!