混凝土配重层对近海海底钢质管道阴极保护效果的影响
王萌萌, 曹国民, 孟繁兴, 李天亮, 宋沁峰, 单太航, 董亮

Influence of Concrete Counterweight Layer on Cathodic Protection Effect of Nearshore Submarine Steel Pipes
WANG Mengmeng, CAO Guomin, MENG Fanxing, LI Tianliang, SONG Qinfeng, SHAN Taihang, DONG Liang
表5 在静态海水和海泥中带混凝土层X60钢的阻抗拟合参数
Table 5 Impedance fitting parameters of concrete weighted X60 steel in static environment
EnvironmentEp, CSE / mVRs / Ω·cm2Cc / F·cm-2Rc / Ω·cm2Cdl / F·cm-2Rp / Ω·cm2
5‰ salinity seawater-806850.31.523 × 10-9206852.051 × 10-441341
-867761.61.526 × 10-9204182.819 × 10-444493
-945813.31.490 × 10-9205133.842 × 10-421283
-1011817.41.488 × 10-9204154.401 × 10-416398
-1068839.11.444 × 10-9202614.103 × 10-414555
-1120875.81.436 × 10-9202303.992 × 10-411554
-1154861.71.479 × 10-9205585.117 × 10-48124
16.8‰ salinity seawater-811220.41.220 × 10-985571.769 × 10-410295
-834490.81.270 × 10-980332.511 × 10-48168
-880319.41.284 × 10-975274.613 × 10-45472
-978210.91.225 × 10-972246.221 × 10-42594
-1076524.11.255 × 10-967914.856 × 10-41640
-1151311.11.181 × 10-964561.032 × 10-31709
-1201510.51.227 × 10-963609.296 × 10-42899
26.7‰ salinity seawater-822574.31.121 × 10-944986.686 × 10-43231
-868562.11.120 × 10-944761.061 × 10-32268
-947581.31.091 × 10-944531.307 × 10-31364
-1019575.81.097 × 10-944181.316 × 10-41036
-10815751.114 × 10-944168.392 × 10-42507
-1149557.91.132 × 10-945286.801 × 10-42155
-1221539.51.158 × 10-945064.529 × 10-41805
Sea mud-7891551.299 × 10-9104012.297 × 10-416877
-8291651.285 × 10-9107793.276 × 10-414086
-896133.71.276 × 10-9111614.821 × 10-410706
-1010154.91.283 × 10-9113206.745 × 10-48185
-108190.581.260 × 10-9114317.529 × 10-46803
-1104160.51.290 × 10-9109415.513 × 10-45293
-1167133.51.259 × 10-9109424.209 × 10-43600