CO2 压力对含杂质超临界CO2 输送管线X65钢应力腐蚀开裂敏感性的影响
程璐瑶, 徐彦磊, 李家玮, 孙冲, 林学强, 孙建波

Effect of CO2 Pressure on Stress Corrosion Cracking Susceptibility of X65 Pipeline Steel Used for Transporting Impure Supercritical CO2
CHENG Luyao, XU Yanlei, LI Jiawei, SUN Chong, LIN Xueqiang, SUN Jianbo
表2 不同CO2压力的含杂质超临界CO2环境中形成液膜中CO2及杂质组分和主要离子的质量与浓度
Table 2 Total mass and concentration of CO2 and impurity components and the mass of main ions in the formed aqueous film calculated by OLI Analyzer Studio software
Chemical7.5 MPa CO210 MPa CO214 MPa CO2
substanceMass / gMass fraction / %Mass / gMass fraction / %Mass / gMass fraction / %
H2O7.000 × 10-495.6353.500 × 10-495.0271.000 × 10-394.595
CO2(aq)3.260 × 10-54.3241.860 × 10-54.9415.936 × 10-55.379
O2(aq)2.441 × 10-103.242 × 10-52.064 × 10-105.486 × 10-51.012 × 10-99.169 × 10-5
H2S(aq)8.805 × 10-91.169 × 10-34.650 × 10-91.236 × 10-31.359 × 10-81.232 × 10-3
NO2(aq)3.738 × 10-84.950 × 10-31.365 × 10-83.622 × 10-32.645 × 10-82.394 × 10-3
SO2(aq)1.936 × 10-77.224 × 10-37.954 × 10-85.455 × 10-31.863 × 10-73.948 × 10-3
H+2.329 × 10-93.093 × 10-41.019 × 10-92.708 × 10-42.585 × 10-92.343 × 10-4
HCO3-8.425 × 10-91.119 × 10-35.471 × 10-91.454 × 10-32.052 × 10-81.860 × 10-3
HS-5.952 × 10-137.902 × 10-83.586 × 10-139.529 × 10-81.222 × 10-121.107 × 10-7
HSO3-1.761 × 10-72.339 × 10-27.468 × 10-81.985 × 10-21.806 × 10-71.637 × 10-2