地下储氢库J55钢氢环境下微生物腐蚀机理研究
姜慧芳, 刘扬豪, 刘莹, 李迎超, 于浩波, 赵博, 陈曦

Mechanism of Microbial Corrosion of J55 Steel in Hydrogen-containing Environments in Underground Hydrogen Storage Facilities
JIANG Huifang, LIU Yanghao, LIU Ying, LI Yingchao, YU Haobo, ZHAO Bo, CHEN Xi
表1 不同条件下培养7 d的J55钢U形弯试样和方形试样的Tafel 曲线拟合的电化学参数。
Table 1 Electrochemical parameters for Tafel curve fitting of U-bend and square specimens of J55 steel incubated for 7 d under different conditions
Experimental conditionIcorr / A·cm-2Ecorr (V) vs. Ag/AgClβa / V·dec-1βc / V·dec-1
Sterile + square specimen9.06 × 10-7-0.7070.105-0.111
Sterile + U-bend specimen1.73 × 10-6-0.6850.063-0.141
SRB + square specimen1.43 × 10-5-0.6230.073-0.041
SRB + U-bend specimen8.05 × 10-5-0.7550.409-0.032
SRB + U-bend specimen + 0.22%H28.18 × 10-5-0.8250.635-0.011
SRB + U-bend specimen + 0.44%H22.32 × 10-4-0.7590.617-0.018