表2 氟橡胶FX-17热空气老化-持久压缩试验lnPτ1.01关系线性回归分析结果
Table 2 Linear regression analysis results of lnP and τ1.01 for fluoroelastomer FX-17 based on hot air aging-sustained compression test data
T / KBiKi / d-1σ2FrR test
5130.77430.05810.0007155.6-0.9843|r| ≥ r0.05 (5) = 0.754
4930.84870.03350.0013156.9-0.9696|r| ≥ r0.05 (10) = 0.576
4730.72120.00890.0023486.7-0.9869|r| ≥ r0.05 (13) = 0.514
4530.81390.00450.0009458.3-0.9882|r| ≥ r0.05 (11) = 0.553
4330.85140.00210.0008130.7-0.9638|r| ≥ r0.05 (10) = 0.576