1, 2, 4-三唑在模拟调相机转子内冷却水中对铜的缓蚀作用
冯礼奎, 程一杰, 宋小宁, 于志勇, 严梓轩, 张大全

Corrosion Inhibition of 1, 2, 4-triazaole on Copper in a Stimulated Cooling Water for Synchronous Condenser
FENG Likui, CHENG Yijie, SONG Xiaoning, YU Zhiyong, YAN Zixuan, ZHANG Daquan
表2 铜电极在含有不同浓度TAZ的模拟内冷水中的电化学阻抗谱拟合参数
Table 2 Fitting parameters of EIS of copper electrode in the simulated cooling solutions with different concentrations of TAZ

TAZ

mmol·L-1

RS

kΩ·cm2

Qf

Rf

kΩ·cm2

Qdl

Rct

kΩ·cm2

Rp

kΩ·cm2

X2

ηE

%

Y0

nS⋅s n ·cm-2

n

Y0

μS·s n ·cm-2

n
Blank2.5653.0100.919.02215.450.64206.1215.1221.28 × 10-3-
11.1191.9600.8715.814.5600.7517711786.811.80 × 10-388.0
50.8490.8050.9235.213.9540.7620522087.217.87 × 10-489.7
101.1501.2220.8923.193.4520.7726592682.191.27 × 10-392.0
151.0951.3290.8816.563.2470.8122692285.569.83 × 10-490.6
201.0860.9990.9228.374.5680.7616211266.716.87 × 10-487.0