压水堆核电厂热态功能试验水化学与设备材料腐蚀关系的研究进展
彭立园, 吴欣强, 张兹瑜, 谭季波

Review on Relationship Between Hot Functional Test Water Chemistry and Corrosion Behavior of Related Component Materials in Pressurized Water Reactor Nuclear Power Plants
PENG Liyuan, WU Xinqiang, ZHANG Ziyu, TAN Jibo
表1 典型HFT和注Zn分步HFT水化学参数对比[19]
Table 1 Comparison of the typical and Zn-injected step-by-step HFT water chemistry parameters[19]
ParameterAP1000 PlantTraditional
Chloride, fluoride, sulfate / µg·L-1≤ 150 (each)≤ 150 (each)
Chemical additionsDuring Heatup PlateauPrior to Heatup
Oxygen / µg·L-1≤ 100≤ 100
Time at NOT/NOP / d1926
Average pH at 292℃7.37.2
Average lithium / mg·L-10.630.51
Average hydrogen / mL·kg-136-
Average zinc / µg·L-146-
Zinc exposure / µg·L-1-months51-
Average boron during cooldown / mg·L-1790-
pHT after cooldown5.0-
Oxygen following H2O2 addition / mg·L-1> 1-