带轧皮预锈钢筋在混凝土养护期间的自然钝化行为研究
刘国强, 张东方, 陈昊翔, 范志宏

Natural Passivation Behavior of Pre-rusted Steel Rebar with Mill Scale in Curing Stage of Concrete
LIU Guoqiang, ZHANG Dongfang, CHEN Haoxiang, FAN Zhihong
表1 2种钢筋动电位极化曲线拟合结果
Table 1 Fitting results of dynamic potential polarization curves for 2 types of steel bars
RebarEcorr / VIcorr / μA·cm-2Ip / μA·cm-2Ep / V
Rusted rebar-0.250.871.54~2.850.37
Normal rebar-0.180.430.79~2.120.40