		| 表5 电流型氢传感器参数 
 | 
	
		| Table 5 Parameter of electrical current hydrogen sensor 
 | 
	
		|  | 
	
		| | Name | Sensitivity μA·mg-1·kg | Range / mg·kg-1 | Response time / s | Temperature range / ℃ | Humidity range RH% | Service life a | 
|---|
 | 4-H2-1000 | 0.02±0.01 | 0-1000 | ≤70 | -20-+50 | 15-90 | 2 |  | 4-H2-40000 | 0.007±0.002 | 0-40000 | ≤60 | -20-+50 | 15-90 | 2 |  | (0-20000) PPM H2 | 0.003±0.002 | 0-20000 | T50:<10 T90:<30 |  |  | >5 |  | (0-1000) PPM H2 ME3-H2 ME4-H2 | 0.008±0.003 0.01±0.005 0.03±0.01 | 0-1000 0-1000 0-1000 | T50:<10 T90:<30 T90:≤90 T90:≤30 | -20-+50 -20-+50 | 15-90 15-90 | >5 2 2 |  | ME2-H2 | 0.002±0.001 | 0-30000 | T90:<30 | -20-+50 | 15-90 | 3 | 
 | 
	
		|  | 
	
		|  |