区域阴极保护数值模拟边界条件反演计算方法研究及应用
庄大伟, 杜艳霞, 陈涛涛, 鲁丹平

Research on Boundary Condition Inversion Method for Numerical Simulation of Regional Cathodic Protection and Its Application
ZHUANG Dawei, DU Yanxia, CHEN Taotao, LU Danping
表1 管道电位偏移和站点反馈数据
Table 1 Potential drift of pipelines and feedback data
Number1# Anode bed2# Anode bed3# Anode bed
VselfvsCSE / VVonvs CSE / VVoffvs CSE / VΔV / mVVonvsCSE / VVoffvsCSE / VΔV / mVVonvsCSE / VVoffvsCSE / VΔV / mV
Area 1A1-0.5-1.46-0.62-120-1.74-0.74-240-1.14-0.68-180
A2-0.49-0.86-0.63-140-1.25-0.75-260-1.03-0.7-210
A3-0.47-0.97-0.62-150-1.37-0.74-270---------
A4-0.47-1.07-0.63-160-1.47-0.75-280---------
A5-0.47-1.05-0.61-140-1.44-0.73-260---------
A6-0.5-1.1-0.63-130-1.45-0.74-240---------
A7-0.48-0.96-0.6-120-1.36-0.7-220---------
A8-0.5-1.01-0.65-150-1.47-0.75-250-1.04-0.7-200
Area 2B1-0.54-0.74-0.59-50-1.57-0.72-180-0.82-0.65-110
B2-0.44-0.64-0.56-120-1.11-0.69-250-0.78-0.63-190
B3-0.47---------------------------
B4-0.55----------1.11-0.75-200-0.8-0.66-110
B5-0.47---------------------------
B6-0.55-0.75-0.66-110-1.19-0.8-250-0.88-0.71-160
B7-0.49---------------------------
B8-0.47----------1.3-0.79-320-0.82-0.63-160
B9-0.54---------------------------
B10-0.44-0.65-0.52-80-1.17-0.67-230-0.88-0.64-200
B11-0.52---------------------------
B12-0.52-0.7-0.57-50-1.24-0.68-160-0.88-0.64-120
B13-0.46---------------------------
B14-0.46-0.75-0.59-130-1.14-0.68-220-1.11-0.69-230
B15-0.48---------------------------
B16-0.47-0.8-0.59-120-1.2-0.7-230-1.25-0.71-240
B17-0.47-0.84-0.59-120-1.23-0.66-190-1.57-0.7-230
B18-0.49-------------------1.64-0.72-230
B19-0.48-0.75-0.57-90----------3.32-0.84-360
B20-0.42-0.69-0.54-120----------1.39-0.63---
B21-0.48, (-0.42~-0.52)-------------------1.29------
Area 3C1----------------------3.96-0.87-870