基于正交方法研究阴极保护电位波动下X100管线钢的点蚀行为
戴明杰, 刘静, 黄峰, 胡骞, 李爽

Pitting Corrosion Behavior of X100 Pipeline Steel in a Simulated Acidic Soil Solution under Fluctuated Cathodic Protection Potentials Based on Orthogonal Method
DAI Mingjie, LIU Jing, HUANG Feng, HU Qian, LI Shuang
表2 试验点蚀统计结果及极差分析
Table 2 Pitting statistical results and range analysis of orthogonal test
Test numberFactorsPitting density mm-2
A (potential fluctuation frequency f ) / HzB (potential fluctuation range E) / VC (duty cycleδ) / %D (total loading time tt) / d
A1B1C1D10.5-0.95~-0.9301645.167
A1B2C2D20.5-0.95~-0.85022379.119
A1B3C3D30.5-0.95~-0.77034249.170
A2B1C2D30.05-0.95~-0.95034151.511
A2B2C3D10.05-0.95~-0.8701551.665
A2B3C1D20.05-0.95~-0.73021739.147
A3B1C3D20.005-0.95~-0.9702906.974
A3B2C1D30.005-0.95~-0.83033220.642
A3B3C2D10.005-0.95~-0.75011293.451
K17273.4565703.6535604.9562490.283---
K26442.3236151.4267824.0815025.240---
K35421.0677281.7685707.80911621.323---
Kˉ12424.4851901.2181868.319830.094---
Kˉ22147.4412050.4752608.0271675.080---
Kˉ31807.0222427.2561902.6033873.774---
Range (R)617.463526.038739.7083043.680---
Factor order3421---
Maximum pitting density combination0.5-0.95~-0.7503---