基于正交方法研究阴极保护电位波动下X100管线钢的点蚀行为
|
戴明杰, 刘静, 黄峰, 胡骞, 李爽
|
Pitting Corrosion Behavior of X100 Pipeline Steel in a Simulated Acidic Soil Solution under Fluctuated Cathodic Protection Potentials Based on Orthogonal Method
|
DAI Mingjie, LIU Jing, HUANG Feng, HU Qian, LI Shuang
|
|
表2 试验点蚀统计结果及极差分析
|
Table 2 Pitting statistical results and range analysis of orthogonal test
|
|
Test number | Factors | Pitting density mm-2 |
---|
A (potential fluctuation frequency f ) / Hz | B (potential fluctuation range E) / V | C (duty cycleδ) / % | D (total loading time tt) / d |
---|
A1B1C1D1 | 0.5 | -0.95~-0.9 | 30 | 1 | 645.167 | A1B2C2D2 | 0.5 | -0.95~-0.8 | 50 | 2 | 2379.119 | A1B3C3D3 | 0.5 | -0.95~-0.7 | 70 | 3 | 4249.170 | A2B1C2D3 | 0.05 | -0.95~-0.9 | 50 | 3 | 4151.511 | A2B2C3D1 | 0.05 | -0.95~-0.8 | 70 | 1 | 551.665 | A2B3C1D2 | 0.05 | -0.95~-0.7 | 30 | 2 | 1739.147 | A3B1C3D2 | 0.005 | -0.95~-0.9 | 70 | 2 | 906.974 | A3B2C1D3 | 0.005 | -0.95~-0.8 | 30 | 3 | 3220.642 | A3B3C2D1 | 0.005 | -0.95~-0.7 | 50 | 1 | 1293.451 | K1 | 7273.456 | 5703.653 | 5604.956 | 2490.283 | --- | K2 | 6442.323 | 6151.426 | 7824.081 | 5025.240 | --- | K3 | 5421.067 | 7281.768 | 5707.809 | 11621.323 | --- | | 2424.485 | 1901.218 | 1868.319 | 830.094 | --- | | 2147.441 | 2050.475 | 2608.027 | 1675.080 | --- | | 1807.022 | 2427.256 | 1902.603 | 3873.774 | --- | Range (R) | 617.463 | 526.038 | 739.708 | 3043.680 | --- | Factor order | 3 | 4 | 2 | 1 | --- | Maximum pitting density combination | 0.5 | -0.95~-0.7 | 50 | 3 | --- |
|
|
|