阴极保护电位对破损环氧涂层阴极剥离的影响
王贵容,邵亚薇,王艳秋,孟国哲,刘斌

Effect of Applied Cathodic Protection Potential on Cathodic Delamination of Damaged Epoxy Coating
Guirong WANG,Yawei SHAO,Yanqiu WANG,Guozhe MENG,Bin LIU
表2 施加不同保护电位下浸泡1056 h后涂层的剥离距离及剥离面积
Table 2
Potential (vs SCE) /mVMaximum delamination distance from damaged edge / mmMinimum delamination distance from damaged edge / mmDelamination areamm2
OCP4.23.454
-7506.05.1117
-8507.26.3169
-9507.56.9183
-10508.57.8243