3种不同Cr含量Co-20Re-Cr合金在1000和1100 ℃的高温氧化行为
王玲,向军淮,张洪华,覃宋林

High Temperature Oxidation Behavior of Three Co-20Re-xCr Alloys in 3.04×10-5 Pa Oxygen at 1000 and 1100 ℃
Ling WANG,Junhuai XIANG,Honghua ZHANG,Songlin QIN
表2 Co-20Re-xCr (x=20,25,30) 合金在1000和1100 ℃恒温氧化24 h的近似抛物线速率常数
Table 2 Approximate parabolic rate constants Kp of Co-20Re-xCr (x=20, 25, 30) alloys during oxidation at 1000 and 1100 oC for 24 h (g2·cm-4·s-1)
Alloy1000 ℃1100 ℃
Co-20Re-20Cr6.83×10-9 (0~1440 min)1.57×10-8 (0~1440 min)
Co-20Re-25Cr3.73×10-9 (0~1440 min)7.37×10-9 (0~1440 min)
Co-20Re-30Cr1.01×10-9 (0~36 min)2.29×10-11 (0~150 min)
1.92×10-10 (36~500 min)4.24×10-12 (150~500 min)
2.43×10-10 (500~1440 min)2.34×10-10 (500~1440 min)