苯并咪唑衍生物在1 mol/L HCl溶液中对45#碳钢缓蚀行为的研究
王青, 马雪梅, 石海燕, 原珊, 郭建峰, 梁栋, 胡志勇

Inhibition Performance of Benzimidazole Derivatives for Steel 45(GB) in 1 mol/L HCl Solution
WANG Qing, MA Xuemei, SHI Haiyan, YUAN Shan, GUO Jianfeng, LIANG Dong, HU Zhiyong
表2 45碳钢在添加不同浓度缓蚀剂的1 mol/L HCl溶液中的阻抗拟合参数
Table 2 Impedance data of 45(GB) steel in 1 mol/L HCl solutions containing different concentrations of inhibitors
Inhibitor c / (gL-1) Rs / (Ωcm2) Rct / (Ωcm2) Cdl / (μFcm-2) IE / %
Blank 1.622 7.695 687.9 ---
0.15 1.271 10.74 409.9 28.4%
0.30 1.451 11.50 240.1 33.1%
2-aminobenzimidazole 0.45 1.074 12.28 223.5 37.3%
0. 60 1.313 13.46 106.3 42.8%
0.75 1.294 16.44 102.5 53.2%
0.90 1.110 19.17 82.26 59.8%
Blank 1.622 7.695 687.9 ---
0.15 1.179 15.69 199.6 50.9%
0.30 1.116 26.89 134.1 71.4%
BSC6T 0.45 1.323 76.29 109.3 89.9%
0.60 1.166 103.4 91.33 92.6%
0.75 1.300 204.7 68.53 96.2%
0.90 1.200 329.8 17.01 97.7%
Blank 1.622 7.695 687.9 ---
0.15 1.327 41.96 280 81.7%
0.30 1.266 58.85 239 86.9%
BSC8T 0.45 1.182 80.81 31.02 90.5%
0.60 1.426 155.4 23.56 95.0%
0.75 1.498 329.5 22.25 97.7%
0.90 1.244 556.1 11.52 98.6%