Abstract In this paper,a method was proposed to determine the critical pitting potential(φcb)which is obtained by extrapolating the curve of 1/φvsφ to 1/τ=0.A formula,φL=φ_(ε,o)+η_(co),was then derived to calculate the limit free corrosion potentials(φ)of practical passive systems. Finally,the boundary condition for prevention of practical passive sys- tems from pitting initiation was established.That is,if φ_(cb)>φfor a practical passive system,it is impossible for pitting nuclei to oc cur in the system,on the contrary,it is possible if φ_(cb)<φ■.
|
Received: 25 February 1989
|
[1] Pourbaix,M.;et al.,Corros.Sci.,3,239(1963) [2] Schwenk,W.,Corrosion,20,129(1964) ;Corros,Sci.,5,245(1965) [3] Herbsleb,G.,Werkstoffe Korros.,16,929(1965) [4] Davies,D.E.;Lotlikar,M.M.,Brit.Corros.J.,1,149(1966) [5] Hospodaruk,V.;Petrocelli,J.V.,J.Electrochem.Soc.,113,878(1966) [6] Leckie,P.,J.Electrochem.Soc.,117,1152(1970) [7] 朱一帆,潘郁,魏宝明,南京化工学院学报,8(3) ,18(1986) [8] Wei Baoming;Hao Ling,J.Nanjing Inst.of Chem.Tech.,9,1(1987) [9] Guilio Milazzo;Sergio Caroli,“Tables of Standard Electrode Potentials”,Chichester Wiley,P.68,(1978) [10] 查全性,《电极过程动力学导论》,科学出版社,P.290,(1976) [11] 魏宝明主编.《金属腐蚀理论及应用》,化学工业出版社,P.105,(1984) |
No Suggested Reading articles found! |
|
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|