水下钢铁构筑物腐蚀监/检测电化学传感系统研制
万小山;田 斌;宋诗哲
天津大学材料学院
STUDY ON THE ELECTROCHEMICAL SENSING SYSTEMFOR MONITORING/DETECTING MARINE STEEL CORROSION
Xiaoshan Wan;Bin Tian;Shizhe Song
天津大学材料学院
全文: PDF(168 KB)  
摘要: 设计制作了能对水下大型钢铁构筑物直接测试的小孔限流型 腐蚀传感器,讨论了影响其测试面积的结构因素,设计了相应的测试仪器,并成功地在塘沽 集装箱码头泊位裸露钢管桩上进行了现场测试.
关键词 腐蚀监/检测电化学传感器测试系统    
Abstract:An electrochemical sensor constraining the measurin g current through a pinhole for directly monitoring/detecting corrosion of marin e steel construction was designed and made.Props with powerful magnetic magnet a nd a retractable tentacle were employed to fix on the surface of ferromagnetism metal material such as iron and steel and to ensure the electricity contact.The influence of structure parameters on its measurement area were discussed.A set o f instrument fitting field measurement,based on the control of singlechip comp uter was designed and made.The field measurements on bare steel tubular stakes o f No.27 container berth in Tanggu were successfully conducted,and the suitabilit y of the designed system in the circumstance of field corrosion monitoring/detec ting was proved.
Key wordscorrosion monitoring/detecting    electrochemical sensor    measurement system
收稿日期: 2000-10-13     
ZTFLH:  TG174  
通讯作者: 万小山   
Corresponding author: Xiaoshan Wan   

引用本文:

万小山; 田斌; 宋诗哲 . 水下钢铁构筑物腐蚀监/检测电化学传感系统研制[J]. 中国腐蚀与防护学报, 2001, 21(3): 182-187 .
Xiaoshan Wan, Bin Tian, Shizhe Song. STUDY ON THE ELECTROCHEMICAL SENSING SYSTEMFOR MONITORING/DETECTING MARINE STEEL CORROSION. J Chin Soc Corr Pro, 2001, 21(3): 182-187 .

链接本文:

https://www.jcscp.org/CN/      或      https://www.jcscp.org/CN/Y2001/V21/I3/182

[1]YojuImao,KazuoOsato,HirojiNakauchi.Calculationofthepolarizationcurrentdistributionanditseffectonthevaluesofthepolarizationresistanceobtainedinmonitoringofcorrosionbylinearpolarizationmethod[C].BoshokuGijutsu,1986,35(12):689-697
[2]SudohS ,HaruyamaS .Currentprofilebetweenprobeelectrodeandlargescaleburiedinstallationinpolarizationresistancemea surement[J].CorrosionEngineering1990,39(2):55-66
[3]FuekiK ,ShiokawaJ,SuzukiS .ACorrosionmonitoringsensorformarinesteelstructures[A].Int.MeetingonChemicalSensors[C],Fukueka,1983,9:9-12
[4]KazumiMatsuoka,SatoshiIto.Electrochemicaldiagnosticanalysisforcorrosiondeteriorationofsteelstructure[J].Zairyo-to-Kankyo,1992,41(10):698-705
[5]FeliuS ,GonzalezJA ,AndradeC ,FeliuV ,On-sitedeterminationofthepolarizationresistanceinareinforcedconcretebeam[J].Corrosion,1988,44(10):761-765
[6]FeliuS ,GonzalezJA ,EscuderoML ,FeliuSJr.Possibilitiesofthe“guardring”fortheconfinementoftheelectricalsignal.Po larizationMeasurementsofReinforcements[A].Corrosion89[C],April,17-21,1989,paperNo.623
[7]FeliuS ,GonzalezJA ,FeliuSJr,AndradeMC .Confinementoftheelectricalsignalforinsitumeasurementofpolarizationresis tanceinreinforcedconcrete[J].ACIMateralsJournal,1990,87(5):457-460
[1] 朱泽洁,张勤号,刘盼,张鉴清,曹发和. 微型电化学传感器在界面微区pH值监测中的应用[J]. 中国腐蚀与防护学报, 2019, 39(5): 367-374.
[2] 郑安升; 宋诗哲 . 水环境中焊接件腐蚀电化学传感器的研制[J]. 中国腐蚀与防护学报, 2006, 26(6): 329-331 .