中国腐蚀与防护学报  1995, Vol. 15 Issue (4): 261-266    
  研究报告 本期目录 | 过刊浏览 |
模拟宫腔液中铜腐蚀行为的研究
张承典;徐乃欣;陆菊芳;丁翠红;杨秉炎
中国科学院上海冶金研究所;中国福利会国际和平妇幼保健院
AN INVESTIGATION ON CORROSION BEHAVIOUR OF COPPER IN SIMULATED UTERIUE FLUID
Zhang Chengdian;Xu Naixin; Lu Jufang;Ding Cuihong(Shanghai Institute of Metallurgy;Chinese Academy of Sciences)Yang Bingyan(The International Peace Maternity and Child Health Hospital of the Chinese Welfare Institute)
全文: PDF(487 KB)  
摘要: 铜在模拟宫腔液中腐蚀后,溶液分析和表面膜阴极还原都证明,以离子形态进入溶液的铜在腐蚀总量中所占的比例随溶液pH而不同。pH7时约占三分之一。当pH降低,这个比例明显增大。模拟宫腔液中溶解氧对铜腐蚀的影响,由于促进溶解和有利成膜的两个相反的作用,在某个氧分压下腐蚀速度出现极大值,pH7和pH8时分别为0.12atm和0.06atm。根据铜的自然腐蚀电位随介质pH的变化,应用Cu-Cl-H2O的电位-pH图解释了这一腐蚀过程。
关键词 铜腐蚀宫内节育器E-pH图    
Abstract:Corrosion behaviour of copper in simulated uterine fluid was investigated by electrochemical and chemical means. Both cathodic reduction of surface film and chemical analysis of solution after corrosion testing proved that the percentage of ionic copper in the corrosion products varied with the pH level of the fluid. About one-third of the total amount of the corroded copper was soluble at pH 7. The share of the soluble products increassed significantly with decreasing pH. In order to examine the effect of oxygen dissolved in the test fluid, the instantaneous corrosion rates under different oxygen pressures were determined using polarization resistance method. A maximum of corrosion rate was observed at a certain oxygen pressure. They were 0.12 atm for pH 7 and 0.06 atm for pH 8, respectively. Based on the variation of the natural corrosion potential of copper with environmentlal pH, the corrosion process was interpreted using E-pH diagram for Cu-Cl-H2O system.
Key wordsCopper corrosion    Intrauterine contraception device    E-pH diagram
收稿日期: 1995-08-25     
基金资助:国家计划生育委员会计划生育科研项目;;腐蚀与防护国家重点实验室资助

引用本文:

张承典;徐乃欣;陆菊芳;丁翠红;杨秉炎. 模拟宫腔液中铜腐蚀行为的研究[J]. 中国腐蚀与防护学报, 1995, 15(4): 261-266.
. AN INVESTIGATION ON CORROSION BEHAVIOUR OF COPPER IN SIMULATED UTERIUE FLUID. J Chin Soc Corr Pro, 1995, 15(4): 261-266.

链接本文:

https://www.jcscp.org/CN/      或      https://www.jcscp.org/CN/Y1995/V15/I4/261

1张承典,徐乃欣,杨秉炎.生殖与避孕,1994,14(3):1632张承典,徐乃欣,陆菊芳,丁翠红,杨秉炎.生殖与避孕,1995,15(1):283KosonenA.FertilityandSterility,1978,30(1):594LewisKN,ArcherRD.Contraception,1977,15(1):935KosonenA.inMedicatedIntrauterineDevices,HafezandOs,vanWAA,edited,MartinusNijhottPress,1981;p22-296杨熙珍,杨武.金属腐蚀电化学热力学电位-pH图及其应用,北京:化学工业出版社,1991,p357金碧华,黄祝玲,周建德.生殖与避孕,1983,3(3):32
[1] 余建飞;江莉;甘复兴. 3-氨基-5-巯基-1,2,4-三唑在除盐水中对Cu的缓蚀作用[J]. 中国腐蚀与防护学报, 2010, 30(1): 21-24.
[2] 黄军波 吴欣强 韩恩厚 柯 伟. 材料在高温高压水溶液中的电化学行为研究现状与进展[J]. 中国腐蚀与防护学报, 2008, 28(6期): 374-380.
[3] 朱建军; 徐乃欣; 张承典 . 血清白蛋白对模拟宫腔液中铜腐蚀的影响[J]. 中国腐蚀与防护学报, 2000, 20(2): 81-87 .
[4] 薛华实;徐乃欣;张承典;陈月贞;沈怡韵. 活性γ型宫内节育器中消炎痛对铜与不锈钢电偶腐蚀的影响[J]. 中国腐蚀与防护学报, 1998, 18(2): 81-86.