埋地管道交流干扰与阴极保护相互作用研究进展 |
唐德志, 杜艳霞, 路民旭, 董亮, 姜子涛 |
北京科技大学新材料技术研究院 北京 100083 |
|
Progress in the Mutual Effects Between AC Interference and the Cathodic Protection of Buried Pipelines |
TANG Dezhi, DU Yanxia, LU Minxu, DONG Liang, JIANG Zitao |
Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083,China |
引用本文:
唐德志, 杜艳霞, 路民旭, 董亮, 姜子涛. 埋地管道交流干扰与阴极保护相互作用研究进展[J]. 中国腐蚀与防护学报, 2013, 33(5): 351-356.
TANG Dezhi,
DU Yanxia,
LU Minxu,
DONG Liang,
JIANG Zitao.
Progress in the Mutual Effects Between AC Interference and the Cathodic Protection of Buried Pipelines. Journal of Chinese Society for Corrosion and protection, 2013, 33(5): 351-356.
链接本文:
https://www.jcscp.org/CN/
或
https://www.jcscp.org/CN/Y2013/V33/I5/351
|
[1] Baeckrnann W V, Schwenk W, Prinz W. Handbook of Cathodic Corrosion Protection [M]. Houston: Gulf Professional Publishing, 1997 [2] Gummow R A, Wakelin R G, Segall S M. AC corrosion-a new challenge to pipeline integrity [A]. Corrosion/1998 [C]. Houston, Texas: NACE, 1998: 98566 [3] Wakelin R G, Gummow R A, Segall S M. AC corrosion-ease histories, test procedures, mitigation [A]. Corrosion/1998 [C]. Houston, Texas: NACE, 1998: 98565 [4] Roger F. Testing and mitigation of AC corrosion on 8# line: a field study [A]. Corrosion/2004 [C]. Houston, Texas: NACE, 2004: 04210 [5] Hanson H R, Jack S. AC corrosion on a pipeline located in an HVAC utility corridor [A]. Corrosion/2004 [C]. Houston, Texas: NACE, 2004: 04209 [6] NACE TG 327 2007-02-08. AC corrosion state-of-the-art: Corrosion rate, mechanism, and mitigation requirements [S] [7] Dévay J, Szegedi R, Labody I. Effect of alternating current on the electrolytic corrosion of steel [J]. Acta Chim. Hung., 1964, 42:191-226 [8] Chin D T, Venkatesh S. A study of alternating voltage modulation on the polarization of mild steel [J]. J. Electrochem. Soc., 1979, 126: 1908-1913 [9] Pookote S R, Chin D T. Effect of alternating current on the underground corrosion of steels [J]. Mater. Perform., 1978, 17(3): 9-15 [10] Kajiyama F, Nakamura Y. Effect of induced alternating current voltage on cathodically protected pipelines paralleling electric power transmission lines [J]. Corrosion, 1999, 55(2): 200-205 [11] Kouloumbi N, Batis G, Kioupis N, et al. Study of the effect of AC-interference on the cathodic protection of a gas pipeline [J]. Anti-corros. Methods Mater., 2002, 49(5): 335-345 [12] Lalvani S B, Lin X A. A theoretical approach for predicting AC-induced corrosion [J]. Corros. Sci., 1994, 36(6): 1039-1046 [13] Ding Q M, Wang H, Lv H L, et al. Electrochemical study on impact of AC on cathodic protection potential for X70 steel [J]. Corros. Prot., 2011, 32(12): 984-987 (丁清苗, 王辉, 吕毫龙等. 电化学方法研究交流干扰对阴极保护电位的影响 [J]. 腐蚀与防护, 2011, 32(12): 984-987) [14] Du C Y. The impact of AC interference on cathodic protection systems of buried pipelines [D]. Beijng: University of Science &Technology Beijing, 2007 (杜晨阳. 交流电干扰对埋地管道阴极保护系统的影响 [D]. 北京: 北京科技大学, 2007) [15] Cao B, Liu K W, Wu Y S. The effect of conductive coupling AC interference on cathodic protection systems [A]. 5th Corrosion Conference of China [C]. Beijing, 2009 (曹备, 刘科伟, 吴荫顺. 电阻耦合型交流干扰对阴极保护系统的影响[A]. 第五届全国腐蚀大会论文集 [C]. 北京, 2009) [16] Pookote S R, Chin D T. Effect of alternating current on underground corrosion of steels [J]. Mater. Perform., 1978, 17(3):9-15 [17] Freiman L I, Yunovich M. Special behavior of steel cathode in soil and protection assessment of underground pipe with a buried coupon [J]. Prot. Met., 1991, 27(3): 437-447 [18] Gong J B, Xu N X, Zhang C D. The effect of AC interference on electrochemical performance of AZ41 magnesium sacrificial anode[J]. J. Chin. Soc. Corros. Prot., 1998, 18(2): 21-26 (龚金保, 徐乃欣, 张承典. 交流电干扰对镁合金AZ41牺牲阳极 电化学性能的影响 [J]. 中国腐蚀与防护学报, 1998, 18(2): 21-26) [19] Bruckner W H. Electrochemical methods for the study of corrosion lead-encased water pipe and cables [J]. Corrosion, 1965, 8:135-136 [20] Yin K H, Tang M H, Xiong X J. Corrosion of buried steel structure under effect of electrical field with industry frequency [J]. J. Chin. Soc. Corros. Prot., 1982, 2(3): 33-41 (尹可华, 唐明华, 熊祥键. 埋地钢构筑物在工频电场作用下的腐蚀 [J]. 中国腐蚀与防护学报, 1982, 2(3): 33-41) [21] CEOCOR-2001, AC corrosion on buried metallic pipeline-guidelines for risk assessment and mitigation measures [S] [22] Li Z L, Yang Y. Mechanism, influence factors and risk evaluation of metal alternating current corrosion [J]. CIESC J., 2011, 62(7):1790-1799 (李自力, 杨燕. 金属材料交流腐蚀机理、影响因素及风险评价[J]. 化工学报, 2011, 62(7): 1790-1799) [23] Philippe C. AC corrosion: detection, investigations and mechanisms [A]. Eurocorr/2003 [C]. Budapest, Hungary, 2003: 307 [24] Ormellese M, Lazzari L, Goidanich S, et al. CP criteria assessment in presence of AC interference [A]. Corrosion/2008 [C]. Houston, Texas: NACE, 2008: 08064 [25] Fu A Q, Cheng Y F. Corrosion of pipeline steel in the presence of alternating current and the new CP recommendation [A]. Proceeding of the 8th International Pipeline Conference [C]. Calgary Alberta, 2010: 31658 [26] Zhang G X. The effect of HVAC transmission lines on the corrosion behavior of buried pipelines [J]. Oil Gas Storage Transp., 2010, 30(2): 125-132 (张贵喜. 高压输电线路对埋地钢质管道的腐蚀影响 [J]. 油气储运, 2010, 30(2): 125-132) [27] Guo X P, Zhang H M, Tang Y F. Determination of the optimum cathodic protection potential [J]. Corros. Sci. Prot. Technol., 1989, 1(2): 6-9 (郭兴蓬, 张华民, 唐永凡. 阴极保护最佳电位的确定 [J]. 腐蚀科学与防护技术, 1989, 1(2): 6-9) [28] Xu N X, Zhang C D. Application of electrochemical impedance spectroscopy to cathodic protection study [J]. Corros. Prot., 1996, 18(2): 7-11 (徐乃欣, 张承典. 用电化学阻抗技术研究阴极保护 [J]. 腐蚀与防护, 1996, 18(2): 7- 11) [29] Wu J X, Fu Z G. AC impedance characteristics of low alloy steels under cathodic protection and determination of the optimum protection potential [J]. J. Chin. Soc. Corros. Prot., 1989, 9(2): 160-164 (吴继勋, 傅争光. 用交流阻抗技术确定船用钢的最佳阴极保护电位 [J]. 中国腐蚀与防护学报, 1989, 9(2): 160-164) [30] Li Z L, Ding Q M, Zhang Y F, et al. Optimal cathodic protection potential for X70 steel with AC interference determined by electrochemical methods [J]. Corros. Prot., 2010, 31(6): 436-439 (李自力, 丁清苗, 张迎芳等. 用电化学方法建立交流干扰下X70 钢的最佳阴极保护电位 [J]. 腐蚀与防护, 2010, 31(6): 436-439) [31] Panossian Z. Effect of alternating current by high power lines Voltage and electric transmission systems in pipelines corrosion [A]. Corrosion/2009 [C]. Houston, Texas: NACE, 2009: 09541 [32] CEN/TS 15280:2006, Evaluation of a.c. corrosion likelihood of buried pipelines-application to cathodically protected pipelines [S] [33] Hosokawa Y, Kajiyama Y, Nakamura Y. New CP criteria for elimination the risks of AC corrosion and overprotection on cathodically protected pipelines [A]. Corrosion/2002 [C], Houston, Texas: NACE, 2002: 02111 [34] Hu S X, Lu M X, Du Y X, et al. New opinions about the AC corrosion of pipelines [J]. Corros. Prot., 2010, 31(6): 419-424 (胡士信, 路民旭, 杜艳霞等. 管道交流腐蚀的新观点[J]. 腐蚀与防护, 2010, 31(6): 419-424) [35] Frazier M J. Induced AC Influence on Pipeline Corrosion and Coating Disbondment [R]. Northwestern Univ., Evanston, IL (United States). Basic Industrial Research Lab, 1994 [36] Yunovich M, Neil G, Thompson. AC Corrosion: corrosion rate and mitigation requirements [A]. Corrosion/2004 [C], Houston, Texas: NACE, 2004: 04206 [37] McCollum B, Ahlborn G H. The influence of frequency of alternating or infrequently reversed current on electrolytic corrosion [J]. J. Franklin Inst., 1916, 182(1): 108-110 [38] Williams J. Corrosion of metals under the influence of alternating current [J]. Mater. Prot., 1966, 5(2): 52 [39] Bruckner W H. The effects of 60 cycle alternating current on the corrosion of steels and other metals buried in soils [R]. Illinois: Engineering Experiment Station Bulletin 470, University of Illinois, Urbana, 1964 [40] Goidanich S. Influence of AC on corrosion kinetics for carbon steel, zinc and copper [A]. Corrosion/2005 [C]. Houston, Texas: NACE, 2005: 05189 [41] Jones D A. Effect of alternating current on corrosion of low alloy and carbon steels [J]. Corrosion, 1978, 34(12): 428-433 [42] Pookote S R, Chin D T. Effect of alternating current on the underground corrosion of steels [J]. Mater. Perform., 1978, 17(3): 9-15 [43] Chin D T, Fu T W. Corrosion by alternating current: a study of the anodic polarization of mild steel in Na2SO4 solution [J]. Corrosion, 1979, 35(11): 514-523 [44] Hamlint A W. Some effects of alternating current on pipeline operations [J]. Mater. Perform., 1986, 25 (1): 57-62 [45] Nielsen L V, Nielsen K V. AC-induced corrosion in pipelines: detection, characterization and mitigation [A]. Corrosion/2004 [C], Houston, Texas: NACE, 2004: 04211 [46] Nielsen L V, Cohn P. AC corrosion in pipelines: Field experiences from a highly corrosive test site using ER corrosivity probes [A]. CEOCOR 2003 [C]. Brussels, Belgium, 2003 [47] Nielsen L V. On-Site measurements of AC induced corrosion: effects of AC and DC parameters [A]. CEOCOR 7 th International Congress [C]. Brussels, Belgium, 2005 [48] Nielsen L V. Investigating AC and DC stray current corrosion [A]. CEOCOR 7th International Congress [C]. Brussels, Belgium, 2005 [49] Nielsen L V. A field study of line currents and corrosion rate measurements in a pipeline critically interfered with AC and DC stray currents [A]. CEOCOR 2006 [C]. Brussels, Belgium, 2006 [50] Nielsen L V. Differential ER-technology for measuring degree of accumulated corrosion as well as instant corrosion rate [A]. Corrosion/2003 [C]. Houston, Texas: NACE, 2003: 03443 [51] Nielsen L V, Galsgaard F. Sensor technology for on-line monitoring of AC-induced corrosion along pipelines [A]. Corrosion/2005[C], Houston, Texas: NACE, 2005: 05375 [52] Panossian Z. Effect of alternating current by high power lines voltage and electric transmission systems in pipelines corrosion [A]. Corrosion/2009 [C]. Houston, Texas: NACE, 2009: 09541 [53] Büchler M, Schoneich H G. Investigation of alternating current corrosion of cathodically protected pipelines: development of a detection method, mitigating measures, and a model for the mechanism [J]. Corrosion, 2009, 65(9): 579-586 |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|