中国腐蚀与防护学报  1988, Vol. 8 Issue (3): 258-266    
  研究报告 本期目录 | 过刊浏览 |
再生器中奥氏体不锈钢取热盘管失效原因分析
史耀武;党耀星;樊培丽
西安交通大学;西安交通大学;西安交通大学
FAILURE ANALYSIS OF HEAT COIL MADE OF AUSTENITIC STAINLESS STEELS IN AN OIL REFINERY UNIT
Shi Yaowu Dang Yaoxing and Fan Peili (Xi'an Jiao—tong University)
全文: PDF(4120 KB)  
摘要: 分析表明炼油厂催化裂化装置再生器取热盘管失效的主要原因是腐蚀疲劳。本文就该实际工程条件下,对1Cr18Ni9Ti及1Cr25Ni20两类奥氏体不锈钢在高温含微量氯离子水中的腐蚀疲劳现象及成因进行了讨论。改善汽水流动条件可显著延长盘管的使用寿命。
Abstract:Heat coils made of austenitic stainless steels were installed in fluidized bed of an actifier of catalytic cracker installation in an oil refinery unit. Steam—water mixture circulated within the coils with high pressure. Corrosion fatigue failure occurred in the coils in about 40 days after commissioning of the unit. In the present paper, corrosion fatigue phenomenon of austenitic stainless steels in high temperature,high pressure water was discussed in the real engineering condition. It was indicated that the lifetime of the coils could be largely increased by improving the steamwater flow condition.
收稿日期: 1988-06-25     

引用本文:

史耀武;党耀星;樊培丽. 再生器中奥氏体不锈钢取热盘管失效原因分析[J]. 中国腐蚀与防护学报, 1988, 8(3): 258-266.
. FAILURE ANALYSIS OF HEAT COIL MADE OF AUSTENITIC STAINLESS STEELS IN AN OIL REFINERY UNIT. J Chin Soc Corr Pro, 1988, 8(3): 258-266.

链接本文:

https://www.jcscp.org/CN/      或      https://www.jcscp.org/CN/Y1988/V8/I3/258

[1] 张硕德,皮运鹏,陈锡祚.炼油设计,1,42~47。(1985)
[2] 唐述德,炼油设计,4,29~35(1986)
[3] 成振武,石油化工设备,10,34~38(1986) 。
[4] 史耀武,炼油厂催化裂化装置再生器取热盘管失效原因及其综合治理方案,研究报告,西安交通大学,(1986)
[5] Payer, J. H., Staehle, R. W., Corrosion Fatigue, NACE-2 Publication, Texas, 211~269(1972)
[6] Failure Analysis and Prevention, Metals Handbook, Vol. 10, 8 th Edition, ASM, (1975) .
[7] Hertzberg, R. W.,Deformation and Fracture Mechanics of Engineering Materials, John Wiley and Sons, (1976) .
[8] 陈学俊,陈听宽,锅炉原理(下册),机械工业出版社,1985年.